Reducing automated dispensing cabinet overrides in the peri-anesthesia care unit: a quality improvement project.

Franciscovich CD, Bieniek A, Dunn K, et al. Reducing automated dispensing cabinet overrides in the peri-anesthesia care unit: a quality improvement project. Jt Comm J Qual Patient Saf. 2024;Epub Sep 24. doi:10.1016/j.jcjq.2024.08.006.

Save
Print
October 23, 2024
Franciscovich CD, Bieniek A, Dunn K, et al. Jt Comm J Qual Patient Saf. 2024;Epub Sep 24.
View more articles from the same authors.

Automated dispensing cabinets (ADC) can improve efficiency in drug administration but pose risks when pharmacist approval is improperly or frequently overridden. This article describes a children's hospital's intervention to decrease ADC overrides in the peri-anesthesia care unit, with a secondary focus on midazolam overrides. The overall override rate decreased from 17% to 4% by the end of the 18-month project period, with a decrease from 22% to 3% for midazolam. While not an aim of the project, time to pharmacist verification also decreased, thus potentially lessening the need for overrides.