Sorry, you need to enable JavaScript to visit this website.
Skip to main content
Study

An automated, dynamic radiation oncology prescription checking system.

Pashtan IM, Kosak T, Shin K-Y, et al. An automated, dynamic radiation oncology prescription checking system. Pract Radiat Oncol. 2024;14(4):343-352. doi:10.1016/j.prro.2023.12.002.

Save
Print
October 23, 2024
Pashtan IM, Kosak T, Shin K-Y, et al. Pract Radiat Oncol. 2024;14(4):343-352.
View more articles from the same authors.

Trigger tools, alerts, and other criteria are used to identify potentially inappropriate prescribing and reduce adverse medication events. In this study, researchers reviewed over 24,000 radiation oncology prescriptions and applied criteria to identify clinically inappropriate prescriptions. The trigger tool generated 241 alerts, 31% of which led to prescription changes.