Sorry, you need to enable JavaScript to visit this website.
Skip to main content
Study

A system analysis of a suboptimal surgical experience.

Lee R, Cooke DL, Richards MR. A system analysis of a suboptimal surgical experience. Patient Saf Surg. 2009;3(1):1. doi:10.1186/1754-9493-3-1.

Save
Print
June 30, 2011
Lee R, Cooke DL, Richards MR. Patient Saf Surg. 2009;3(1):1.
View more articles from the same authors.

A post-surgical complication experienced by one of the authors—himself a patient safety researcher—is examined in detail using root cause analysis.

Save
Print
Cite
Citation

Lee R, Cooke DL, Richards MR. A system analysis of a suboptimal surgical experience. Patient Saf Surg. 2009;3(1):1. doi:10.1186/1754-9493-3-1.