Facilitated self-reported anaesthetic medication errors before and after implementation of a safety bundle and barcode-based safety system.
This pre–post study of errors in anesthesia compared self-reported errors before and after implementation of a medication safety bundle that included smart infusion devices and barcode medication administration. Wrong-medication errors declined after barcoding was introduced, consistent with prior studies.