Study

Electronic detection of delayed test result follow-up in patients with hypothyroidism.

Meyer AND, Murphy DR, Al-Mutairi A, et al. Electronic Detection of Delayed Test Result Follow-Up in Patients with Hypothyroidism. J Gen Intern Med. 2017;32(7). doi:10.1007/s11606-017-3988-z.

Save
Print
April 24, 2018
Meyer AND, Murphy DR, Al-Mutairi A, et al. J Gen Intern Med. 2017;32(7).
View more articles from the same authors.
Trigger tools facilitate identification of adverse events. In this retrospective medical record review study, investigators found that an automated trigger successfully identified delayed follow-up of laboratory thyroid testing among patients with hypothyroidism, with a positive predictive value of 60%. The authors suggest that this trigger approach could be used to detect and ameliorate follow-up delays in real time.
Save
Print
Cite
Citation

Meyer AND, Murphy DR, Al-Mutairi A, et al. Electronic Detection of Delayed Test Result Follow-Up in Patients with Hypothyroidism. J Gen Intern Med. 2017;32(7). doi:10.1007/s11606-017-3988-z.